Heat Pump vs AC Savings Calculator

Would a heat pump save you money over your AC plus furnace? Pick your climate, enter your equipment and utility prices, and see yearly savings and payback.

Flip between summer and winter to see how each system works. The gauge and bars use your numbers below.

1. Your climate

Edit climate hours full-load hrs per year

"Full-load hours" is how many hours a year the system would need to run flat-out to deliver your yearly cooling or heating. Houston and Dallas use values from the Texas Technical Reference Manual. Other cities are planning estimates, not measurements. Edit them if you know better.

2. System size

tons
sq ft

The rule of thumb is only a starting point. Real sizing needs a Manual J load calculation from your contractor.

3. Your current system

% AFUE

4. The new heat pump

SEER2
HSPF2
%

Backup strips use about 3.4 times more electricity per unit of heat than the heat pump itself. About 5% is a reasonable guess for the Gulf Coast. Use 15 to 30% for cold climates.

5. Energy prices and install costs edit to match your bills and quotes

Energy prices

$/kWh
$/therm

Defaults are rounded from recent U.S. Energy Information Administration (EIA) averages for Texas homes. Use the rates on your own bills, including delivery charges.

Install costs

$
$
$

Cost defaults are placeholders, not quotes. Get two or three local quotes. The federal 25C tax credit has ended for 2026 installs, so incentives start at $0. Enter any utility or state rebate you qualify for.

Your estimate

— per year

Yearly cost breakdown cooling, heating, kWh, therms
CurrentHeat pump
Cooling cost——
Heating cost——
Total per year——
Electricity (kWh)——
Gas (therms)——
Payback and 15-year savings
  • Extra cost of heat pump (after incentives)—
  • Simple payback—
  • 15-year net savings—

How this calculator works

Your home needs a certain amount of cooling and heating each year, measured in BTU. The calculator multiplies your system size by the "full-load hours" for your climate, then divides by how efficiently each system turns energy into cooling or heat.

  • Yearly cooling load (BTU) = tons × 12,000 × cooling hours
  • Yearly heating load (BTU) = tons × 12,000 × heating hours
  • Cooling kWh = cooling BTU ÷ (SEER2 × 1,000)
  • Heat pump heating kWh = heating BTU ÷ (HSPF2 × 1,000), plus any share done by backup strips at 3,412 BTU per kWh
  • Gas furnace therms = heating BTU ÷ (AFUE × 100,000)
  • Electric resistance heat = heating BTU ÷ 3,412 per kWh
  • Cost = kWh × your electric rate, therms × your gas rate
  • Simple payback = (heat pump cost − incentives − cost of replacing AC + furnace) ÷ yearly savings. It ignores financing, rate increases and maintenance.

The tool assumes both the old and new system are the same size and that your home needs the same amount of cooling and heating either way. Better-sealed ducts or a different size could change that. The 15-year figure is yearly savings × 15 minus the extra cost, with no energy price increases.

SEER vs SEER2, HSPF vs HSPF2

Equipment made since January 2023 is rated with SEER2 and HSPF2, which use a tougher test. If your old unit shows SEER and HSPF, the calculator converts: SEER2 ≈ SEER × 0.95 and HSPF2 ≈ HSPF × 0.85. These are the RESNET conversion factors for ducted split systems (MINHERS Addendum 71f). The new heat pump is always entered in SEER2 and HSPF2, as on its label.

Where the climate numbers come from

Full-load hours vary a lot with house, thermostat habits, duct quality and how oversized the equipment is. Houston and Dallas use the equivalent full-load hours in the Texas Technical Reference Manual v13, Volume 2, Table 29 (central AC and heat pumps, based on the ENERGY STAR Central AC/HP savings calculator): Houston 2,209 cooling and 1,127 heating hours, Dallas 1,926 and 1,343. Treat the heating hours as generous, because they assume typical installed (often oversized) equipment. Austin / San Antonio is a midpoint of the Dallas and Houston values (an estimate; the TRM has no Austin zone). The other cities are rounded planning estimates that follow each city's degree-day pattern in NOAA's 1991–2020 climate normals, not measured or published values, so they are not directly comparable with the Texas rows. Overwrite the two hours fields with a better number if you have one, such as from an energy audit.

PresetCooling hrsHeating hrs
Houston (Texas TRM)2,2091,127
Dallas-Fort Worth (Texas TRM)1,9261,343
Austin / San Antonio (estimate)2,0701,235
Miami2,500100
Atlanta1,400900
Phoenix2,200450
Charlotte1,2001,100
Denver6001,600
Chicago7001,900
Seattle2501,300
Energy price defaults
  • Electricity, $0.16 per kWh: rounded from the EIA monthly average residential price for Texas in 2026 (about 15.9 to 17 cents). Source: EIA Electric Power Monthly, Table 5.6.A.
  • Natural gas, $1.70 per therm: the EIA Texas residential gas price was about $16 to $19 per thousand cubic feet in early 2026 (EIA Texas natural gas prices). One thousand cubic feet is about 10.4 therms, so that is roughly $1.55 to $1.85 per therm. Summer prices per unit look much higher because fixed monthly charges are spread over very little gas, so the winter number is the better one for heating.
Install cost defaults

The $11,000 (AC plus gas furnace) and $10,500 (ducted heat pump) defaults sit inside the published 2026 ranges for a typical 2.5 to 3 ton replacement on existing ductwork, roughly $5,500 to $13,000 for a furnace and AC and $6,000 to $14,000 for a ducted heat pump. See Angi, HVAC replacement cost and HVACBase, heat pump installation cost. They are placeholders, not quotes.

Is there a federal tax credit?

As of October 2026, no. The 25C Energy Efficient Home Improvement Credit, which covered 30% of heat pump costs up to $2,000 a year, was ended by the One Big Beautiful Bill Act (Public Law 119-21) for property placed in service after December 31, 2025. A heat pump that was installed and working by that date still qualifies on a 2025 tax return. See the IRS FAQs on changes to 25C and other credits. Some electric utilities and states may still offer their own rebates, which are separate. Ask your electric company and contractor, and enter any rebate in the incentives box.

Hot-humid Gulf Coast notes
  • Humidity: in cooling mode a heat pump dehumidifies like any air conditioner. Size matters. An oversized unit short-cycles and leaves the house clammy. Ask for a Manual J load calculation.
  • Backup heat: a few nights a year drop near freezing. Most Houston heat pumps include electric backup strips. The backup box above lets you test how that changes the result.
  • Ducts: leaky attic ducts waste more energy than the gap between two efficiency ratings. Ask about duct sealing and testing.
  • Gas is cheap, electricity less so: where gas is inexpensive, a gas furnace can still be cheaper to run on the coldest days. The heat pump usually wins on cooling efficiency.
  • More background: U.S. Department of Energy, Heat Pump Systems.

This is a planning estimate, not a quote or an energy audit. Actual bills depend on your house, ducts, thermostat habits and weather.

Yearly cost breakdown cooling, heating, kWh, therms
Payback and 15-year savings

How this calculator works

Your home needs a certain amount of cooling and heating each year, measured in BTU. The calculator multiplies your system size by the "full-load hours" for your climate, then divides by how efficiently each system turns energy into cooling or heat.

  • Yearly cooling load (BTU) = tons × 12,000 × cooling hours
  • Yearly heating load (BTU) = tons × 12,000 × heating hours
  • Cooling kWh = cooling BTU ÷ (SEER2 × 1,000)
  • Heat pump heating kWh = heating BTU ÷ (HSPF2 × 1,000), plus any share done by backup strips at 3,412 BTU per kWh
  • Gas furnace therms = heating BTU ÷ (AFUE × 100,000)
  • Electric resistance heat = heating BTU ÷ 3,412 per kWh
  • Cost = kWh × your electric rate, therms × your gas rate
  • Simple payback = (heat pump cost − incentives − cost of replacing AC + furnace) ÷ yearly savings. It ignores financing, rate increases and maintenance.

The tool assumes both the old and new system are the same size and that your home needs the same amount of cooling and heating either way. Better-sealed ducts or a different size could change that. The 15-year figure is yearly savings × 15 minus the extra cost, with no energy price increases.

SEER vs SEER2, HSPF vs HSPF2

Equipment made since January 2023 is rated with SEER2 and HSPF2, which use a tougher test. If your old unit shows SEER and HSPF, the calculator converts: SEER2 ≈ SEER × 0.95 and HSPF2 ≈ HSPF × 0.85. These are the RESNET conversion factors for ducted split systems (MINHERS Addendum 71f). The new heat pump is always entered in SEER2 and HSPF2, as on its label.

Where the climate numbers come from

Full-load hours vary a lot with house, thermostat habits, duct quality and how oversized the equipment is. Houston and Dallas use the equivalent full-load hours in the Texas Technical Reference Manual v13, Volume 2, Table 29 (central AC and heat pumps, based on the ENERGY STAR Central AC/HP savings calculator): Houston 2,209 cooling and 1,127 heating hours, Dallas 1,926 and 1,343. Treat the heating hours as generous, because they assume typical installed (often oversized) equipment. Austin / San Antonio is a midpoint of the Dallas and Houston values (an estimate; the TRM has no Austin zone). The other cities are rounded planning estimates that follow each city's degree-day pattern in NOAA's 1991–2020 climate normals, not measured or published values, so they are not directly comparable with the Texas rows. Overwrite the two hours fields with a better number if you have one, such as from an energy audit.

PresetCooling hrsHeating hrs
Houston (Texas TRM)2,2091,127
Dallas-Fort Worth (Texas TRM)1,9261,343
Austin / San Antonio (estimate)2,0701,235
Miami2,500100
Atlanta1,400900
Phoenix2,200450
Charlotte1,2001,100
Denver6001,600
Chicago7001,900
Seattle2501,300
Energy price defaults
  • Electricity, $0.16 per kWh: rounded from the EIA monthly average residential price for Texas in 2026 (about 15.9 to 17 cents). Source: EIA Electric Power Monthly, Table 5.6.A.
  • Natural gas, $1.70 per therm: the EIA Texas residential gas price was about $16 to $19 per thousand cubic feet in early 2026 (EIA Texas natural gas prices). One thousand cubic feet is about 10.4 therms, so that is roughly $1.55 to $1.85 per therm. Summer prices per unit look much higher because fixed monthly charges are spread over very little gas, so the winter number is the better one for heating.
Install cost defaults

The $11,000 (AC plus gas furnace) and $10,500 (ducted heat pump) defaults sit inside the published 2026 ranges for a typical 2.5 to 3 ton replacement on existing ductwork, roughly $5,500 to $13,000 for a furnace and AC and $6,000 to $14,000 for a ducted heat pump. See Angi, HVAC replacement cost and HVACBase, heat pump installation cost. They are placeholders, not quotes.

Is there a federal tax credit?

As of October 2026, no. The 25C Energy Efficient Home Improvement Credit, which covered 30% of heat pump costs up to $2,000 a year, was ended by the One Big Beautiful Bill Act (Public Law 119-21) for property placed in service after December 31, 2025. A heat pump that was installed and working by that date still qualifies on a 2025 tax return. See the IRS FAQs on changes to 25C and other credits. Some electric utilities and states may still offer their own rebates, which are separate. Ask your electric company and contractor, and enter any rebate in the incentives box.

Hot-humid Gulf Coast notes
  • Humidity: in cooling mode a heat pump dehumidifies like any air conditioner. Size matters. An oversized unit short-cycles and leaves the house clammy. Ask for a Manual J load calculation.
  • Backup heat: a few nights a year drop near freezing. Most Houston heat pumps include electric backup strips. The backup box above lets you test how that changes the result.
  • Ducts: leaky attic ducts waste more energy than the gap between two efficiency ratings. Ask about duct sealing and testing.
  • Gas is cheap, electricity less so: where gas is inexpensive, a gas furnace can still be cheaper to run on the coldest days. The heat pump usually wins on cooling efficiency.
  • More background: U.S. Department of Energy, Heat Pump Systems.

This is a planning estimate, not a quote or an energy audit. Actual bills depend on your house, ducts, thermostat habits and weather.

Estimates only — not engineering, legal or code advice. Check requirements with your local building department and a licensed professional before you build.

Common questions

Is the federal heat pump tax credit still available?

Not for new installs. The 25C Energy Efficient Home Improvement Credit (30% of cost, up to $2,000 a year for heat pumps) was ended by the One Big Beautiful Bill Act for property placed in service after December 31, 2025. If your heat pump was installed and working by that date you can still claim it on your 2025 return. Check with a tax professional, and look for rebates from your electric utility or state, which are separate.

Does a heat pump work in Houston and the Gulf Coast?

Yes. Houston winters are mild, so a heat pump covers nearly all of the heating at high efficiency. In summer it cools exactly like a normal air conditioner. Many Gulf Coast homes keep a small electric heat strip as backup for the few cold nights each year.

Will a heat pump save me money if I have cheap natural gas?

It depends on your gas and electric prices. Gas heating is often cheaper per unit of heat when gas is cheap. In a hot-humid climate like Houston most of the yearly bill is cooling, so a more efficient heat pump (higher SEER2) often saves money on cooling even when heating costs about the same. Use the prices on your own bills.

What is the difference between SEER and SEER2, and HSPF and HSPF2?

They measure the same thing, efficiency, but SEER2 and HSPF2 use a tougher test (since January 2023) that better matches real ductwork. The same unit gets a lower number on the new scale. As a rough conversion, SEER2 is about 0.95 times SEER, and HSPF2 is about 0.85 times HSPF for ducted split systems.

How long does it take for a heat pump to pay back?

If you are replacing a failed AC and furnace anyway, the extra cost of a heat pump is often small, so payback can be quick. If you replace a working system early, payback is usually much longer. This calculator measures payback on the extra cost over replacing the AC and furnace like-for-like.

Does a heat pump dehumidify as well as an air conditioner?

In cooling mode a heat pump is an air conditioner, so it removes moisture the same way. Variable-speed models run longer at low speed and can remove more moisture. Proper sizing matters most. An oversized unit cools quickly but leaves the air clammy.